Add Favorite
WeChat
Hi,Welcome To ENEJEAN Hotoline:8620-36548602 Sitemapsitemap Chinese
Select Language
Thai
Indonesian
Korean
Japanese
Vietnamese
Malay
Russian
Filipino
French
German
Portuguese
Hindi
Xhosa
Arabic
Burmese
Cambodia
Lao
China
Italian
Spanish
Dutch
Greek
Turkish
Bengali
Persian
Poland
Current position:Home-> Industrial washing machine News

Washing equipment maintenance

      1, washing equipment in operation after a period of time.Rotor cage water level change, how to adjust?
      Tip: washing water level detection of pressure equipment, water level detection tube seal damage leakage;Wait a tube into the foreign bodies blocked the change of water level, the device inside the cage is empty water;Wear clothes clean house door open state sure water tube seal level can be normal.If can not adjust for water level detector damage need to change.


      2, after washing equipment running water level inside the cage is keep not to live, how to repair?
      Tip: check the drain valve cylinder two compression after downtime trachea, trachea in undrained condition controller cylinder root with compressed air, compressed gas cylinder at the top, the drain valve plug valves clean house under the foreign body in it can;Such as two endotracheal has compressed gas cylinder or without compressed air, then checks the trachea to solenoid valve can be first.


       3 equipment in the process of washing, washing equipment, rotor cage suddenly stops, the controller prompts converter fault?
       Tip: this failure are generally transducer to detect abnormal protect downtime of equipment operation (such as voltage change; load changes, the control unit from abnormal), the inverter will record the fault information.View the inverter in the wu can targeted treatment, such as prompt overvoltage, would have motor deceleration time is too short, increase inverter deceleration time parameters can be;Such as prompt electronic thermal protection, it would be the inverter heat sink cooling fan too dirty or damaged, clear heat sinks or replace the fan.Such devices inverter specifications will be according to the fault information put forward the solution.


       4, washing equipment, equipment controller will self-check, if there are any abnormal shows fault code, the user according to troubleshoot fault code, how to deal with?
       Tip: # 4 x (# # 40 x temperature sensor short-circuit; 41 x temperature probe open), change the temperature probe can be solved, so the controller has a fault when prompted, check the equipment manual processing.


       5, washing equipment temperature can not control, how to check?
      Tip: equipment heating when the temperature inside the cage to the set temperature heating, the compression on the heating valve trachea, compressed gas repair tracheal pilot electromagnetic valve, no compressed air, steam moving valve maintenance.Temperature is less than the set value but cage temperature higher than the control temperature, damage to the device temperature probe has to change.